Overview>

Products>
 
Electrical Distribution Equipment for Energy Systems
 
Distribution boards for transformation points
Three-phase metering and protection unit in metal/polycarbonate case
Three-phase low voltage selective box
0.4 kV distribution box in metal/polycarbonate case
Connection niche in metal/polycarbonate case
Single-phase metering and protection unit in metal/polycarbonate case
Central point for starting up the public lighting
Level distribution and metering niche in polycarbonate/metal case
Three-phase low voltage junction box
Installation for power factor compensation
 
Low Voltage Electrical Equipment
 
Medium Voltage Electrical Equipment
 
Metallic enclosures
 
Equipment for it and telecom industry
 

Services>

Applications>
   

 

Installation for power factor compensation

It compensates the reactive electrical energy used by the inductive receivers in order to produce a coso>0,92.

Functions 

  • Connection and disconnection of adjustment steps in manual or automatic mode
  • Short-circuit protection for adjustment steps made of safety fuses

Technical features:

Rated reactive power 25 ÷ 400kVAr
Adjustment step number 3 ÷ 12 steps
Rated power 400/230 V a.c.
Rated insulation voltage 690 V a.c.
Rated frequency 50Hz
Protection standard IP 30 (indoor)
IP 54 (outdoor)

 

Component parts

  • Metallic box or metallic cabinet AlfaSystem that provides the IP 30 protection standard (for the indoor variant), respectively the IP 54 protection standard (for the outdoor variant)
  • Three-phase contactors for capacitive load with current limiting resistors
  • Three-phase reactive capacitors with discharging resistors  
  • Automatic regulator for reactive power
  • Short-circuit protection unit
  • Ventilation system (outdoor variant)
  • Thermostat circuit (outdoor variant)
  • Automatic main breaker (optional)
  • Indoor electric circuits made of insulated copper conductors
  • Pressure gaskets for input/output supplying cables

Operating conditions:

Erection location Indoor/outdoor
Climate group WDr/CT (moderate climate: hot dry / cold temperate)
Environment ambient temperature range during operation -25 ÷ 40°C
Environment ambient temperature range during transportation, storing and erection -40 ÷ 50°C
Average ambient temperature in 24 hours 35°C
Air relative humidity Max. 100% at 25°C
Maximum altitude 2000 m
Pollution degree 3
Over-voltage category Category III
Electro-magnetic mediums Environment A
Life span 25 years